InternalPart Class |
Namespace: FactoryLogix.xTend.DataObjects
The InternalPart type exposes the following members.
Name | Description | |
---|---|---|
InternalPart | Initializes a new instance of the InternalPart class |
Name | Description | |
---|---|---|
AssemblyCustomer |
Points to a customer that exists in the customer library in FactoryLogix.
| |
CircuitCount |
Indicate the number of circuits in a panel
| |
ComponentType |
For electronic parts, the general category of the JEDEC package of this part.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
DefaultBakingTime |
For moisture sensitive electronic parts, an integer value indicating the total number of minutes required
to restore the part to original condition based using low temperature baking processes.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
DefaultJEDECLevel |
For moisture sensitive electronic parts, a string value indicating the moisture sensitivity level for this part
as defined by JEDEC.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
DefaultMSDLevel |
For moisture sensitive electronic parts, a string value indicating the moisture sensitivity level for this part
as defined by the FactoryLogix MSD Level setup.
| |
DefaultPasteSettings |
For electronic solder paste, a string value indicating the warmup and exposure settings to be used
as defined by the FactoryLogix Paste Settings setup.
| |
DefaultStockLocation |
A string value describing the stock location identifier of the location in the stock room
where this part is generally stored. It is possible that the part may be stored in more
than one stock location, and in this case, this field simply denotes the primary location.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
FactoryLogix stores part-location affinity as part of the stock definition.
| |
ExternalName |
An alternate part number for this part that may be used by 3rd party's external to the factory.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
FactoryLogix uses the AlternatePartNumbers relationship(s) to designate 1 or more alternate part numbers
for this part.
| |
Handling |
For electronic parts, a set of flags indicating ways in which this part may be handled
during placement, insertion, or overall processing.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
IsAssembly |
Specifies whether or not this particular part in an assembly. An assembly is a part that is
manufactured within the factory environment (as opposed to a part that is purchased as a raw material).
A part can be changed to an assembly using this property but a part that is already an assembly cannot be changed back to a regular part.
| |
IsConfigurable |
A boolean value indicating whether or not this part (assembly) may be built in diffent configurations
on a per Batch (Work Order) basis. This value will be true for parts/assemblies that are built using
CTO processes (Configure To Order).
| |
IsPolarized |
For electronic parts, a boolean value which indicates whether or not this part has polarity (pin 1 significant).
| |
IsRoHS |
A nullable boolean value which indicates whether or not this part is a RoHS compliant part.
A null value indicates the value has not been determined.
(Compliant to the EU Restriction of Hazardous Materials Directive).
| |
IsSocket |
For electronic parts, a boolean value which indicates whether or not this part is a "socket" type part that enables another electronic component to be plugged into it.
| |
IsVariant |
A boolean value indicating whether or not this part is one of several possible CTO build variations for
a particular master, configurable assembly.
| |
MaxBakingTime |
For moisture sensitive electronic parts, an integer value indicating the total number of minutes that the
part may be baked before it must be discarded.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
MaxCoolingCount |
For electronic solder paste, an integer value indicating the total number of time the paste may be refrigerated
before it must be discarded.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
MaximumBakingCount |
For moisture sensitive electronic parts, the total number of times that the part may be
restored to original condition via low temperature baking processes.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
MaxValue |
For electronic parts, the maximum allowable electical value of the component (based on manufacturer tolerances).
| |
MinValue |
For electronic parts, the minimum allowable electical value of the component (based on manufacturer tolerances)
| |
MountingTechnology |
For electronic components, an enumerated value indicated the mounting technology for the part (SMT, Through-Hole, etc.).
| |
NegativeTolerance |
For electronic parts, the maximum allowable percentage below nomimal value (based on manufacturer tolerances)
| |
NominalValue |
For electronic parts, the electical value of the component (e.g. 5 kOhm, 1.3 uF, etc.)
| |
PackageName |
For electronic parts, the name of the JEDEC package type of this part (0805, 1206, SOIC8, etc.)
| |
PackagingSize |
For electronic parts, a friendly description of the size of the packaging (carrier) used to hold this part during production.
For example, SMT components in reel type packaging might be "8mm", "12mm", "16mm", etc.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
PartLabel |
A value that represents the common marking that may be found printed by
the manufacturer on each instance of this part.
| |
PartType |
An enumerated value indicating the general category for a particular part.
| |
PositiveTolerance |
For electronic parts, the maximum allowable percentage above nomimal value (based on manufacturer tolerances)
| |
ProcessingSteps |
For electronic parts, a string value used by the legacy diplan MES system to indicate the
process flow for this part.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
ReceivingProcess |
The name of the FactoryLogix Receiving Process to be used for accepting this part into the factory
as a new raw material. Typically, Receiving Processes are used for IQC (Incoming Quality Control)
purposes, environmental conditioning, or other processes that must be undertaken for this part
whenever a shipment is received at the factory.
| |
ReceivingProcessID |
The ID of the FactoryLogix Receiving Process to be used for accepting this part into the factory
as a new raw material. Typically, Receiving Processes are used for IQC (Incoming Quality Control)
purposes, environmental conditioning, or other processes that must be undertaken for this part
whenever a shipment is received at the factory.
| |
ReleaseStatus |
An enumerated value indicating the A numeric value indicating the weight of a single instance of this part
in units applicable to the part (g, lb, etc.).
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
RoHSValue |
For RoHS regulated parts and materials, an integer value describing the level of hazardous material.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
SimultaneousLoading |
A nullable boolean value indicating whether or not single instances of this part may be loaded at more than one physical location
on the production floor.
| |
SplicingTolerance |
For electronic parts, a numeric value indicating the maximum amount of "overlap" (expressed in number of parts) that
is to be expected when splicing together two reels of this part.
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
| |
UnitOfIssue |
The name or abbreviation of the Unit that this part is measured in. The string value of this property must align with one of the pre-configured unit names
assigned to this attribute via the unit of measure property in the FactoryLogix configuration. Alternatively, a part's Unit of Issue can be set to 'Pieces' (the default value)
by specifying 'Pieces' or 'pcs' here.
| |
VariantPartID |
If this part is a variant, this field represetnts the ID of the master, configurable assembly
of which this part is a variant.
| |
Weight |
A numeric value indicating the weight of a single instance of this part
in units applicable to the part (g, lb, etc.).
THIS FIELD IS NOT UTILIZED BY FACTORYLOGIX, AND IS PROVIDED FOR BACKWARDS COMPATIBILITY WITH LEGACY DIPLAN MODULES ONLY.
|